CPM 30KW Three Phase MPPT Inverter
Brand: Lersion
Product origin: China
Delivery time: 2-15 days
Supply capacity: 170000
Three phase hybrid solar inverter
Germany Infineon IGBT module
America new generation DSP microprocessor chips
12years circuit board self-design and innovation, patent technology
CPM Series 30KW Hybrid Off Grid Inverter
1 Product Features
1. The three-phase inverter adopts a combination of German Infineon IGBT module and high-frequency pulse width modulation technology SPWM, which has higher inverter efficiency, more stable and safe system, and long service life.
2. The inverter adopts American DSP, MCU, and DDC real-time microprocessor chips to achieve full digital circuit control and management, effectively ensuring accurate and fast operation of the core system.
3. A 7-inch high-definition LCD touch screen allows for easy human-computer interaction, viewing device operation data and working status, while also supporting query of operation records and setting of related parameters.
4. Power frequency architecture design, pure sine wave output, precision quality isolation transformer, supporting three-phase unbalanced load, with a complete machine conversion rate of over 95%.
5. The complementary function of mains and battery enables seamless switching between batteries and mains, with optional mains charging function and three-stage charging (constant current, constant voltage, float charging), which adapts to various usage needs and effectively extends the service life of batteries.
6. 3 times the peak power, strong loads capacity, and can adapt to capacitive, resistive, inductive, and mixed loads.
7. Mains/AC priority, battery/DC priority, energy-saving mode optional, and with unmanned function.
8. Equipped with complete protection functions such as AC input over voltage/under voltage, output over voltage/under voltage, under voltage warning, over temperature, overload and short circuit, battery overcharging, etc.
9. Equipped with S232/485 extended communication interface and communication module, it is convenient for users to remotely manage the power generation system.
10. WiFi remote monitoring (optional).
2 Application of CMP 20KW
Residential | Hotel Villa | Ship/island | Farmland | Non grid eara | Factory |
3 Application Diagram of CMP 20KW
4 Technical Parameters
Mode | CPM8K | CPM10K | CPM15K | CPM20K | CPM25K | CPM30K | CPM40K |
Capacity | 8KW | 10KW | 15KW | 20KW | 25KW | 30KW | 40KW |
Battery voltage | 192/220/360/384VDC | ||||||
Size:(L*W*Hmm) | 800*670*1550(W*D*Hmm) | ||||||
package size (L*W*Hmm) | 1070*820*1680(W*D*Hmm) | ||||||
N.W.(KG) | 140 | 150 | 220 | 250 | 280 | 310 | |
G.W.(KG) | 175 | 185 | 255 | 285 | 315 | 345 | |
Input | |||||||
Phase | Three-phase+N+G | ||||||
AC input range | 380VAC±20% | ||||||
Input frequency | 45Hz~55Hz,55Hz~65Hz | ||||||
Output | |||||||
Output voltage | inverter mode:380Vac±3%;AC mode:380Vac±20%; | ||||||
Frequency range (AC mode) | 45Hz~55Hz | ||||||
Frequency range (inverter mode) | 50Hz/60Hz ±0.1Hz | ||||||
Over load capacity | AC mode:(100%~110%:10min;110%~130%:1min;>130%:1s;) | ||||||
inverter mode:(100%~110%:30s;110%~130%:10s;>130%:1s;) | |||||||
Peak current ratio | 3:1max | ||||||
Conversion time | <10ms | ||||||
Waveform | Pure sine wave | ||||||
Harmonic distortion | Linear load<3%;Non-linear load<5% | ||||||
Balance load voltage | <±1% | ||||||
Imbalance load voltage | <±5% | ||||||
Efficiency | 92% | ||||||
Isolation type | output isolation | ||||||
Battery | |||||||
battery capacity | It depends on the use | ||||||
battery number | It depends on the use | ||||||
environmental conditions | |||||||
Operating temperature | 0℃-40℃ (Battery life decreases at ambient temperatures above 25 degrees Celsius) | ||||||
Operation humidity | <95%(without condesing) | ||||||
Operating altitude | <1000m(with increase of 100m,it will reduce output of 1%) max5000m | ||||||
Noise | <58dB(distance to machine 1m) | ||||||
MPPT controller | |||||||
Battery voltage | 192V | 220V | 360V | 384V | |||
PV input voltage range | 260V-400V | 450V-750V | |||||
Max charge current | 50A | 100A | |||||
Max PV input | 192V:10KW,220V:11KW 360V:18KW,384V:19KW | 192V:20KW,220V:22KW 360V:36KW,384V:38KW | |||||
Management | |||||||
Display | 7inch touch screen system | ||||||
Computer communication interface | RS232,(485、Network remote monitoring options) | ||||||
*The above data is for reference. If there is any change, please refer to the real object. |
5. Working mode of CPM
CPM series 3-phase solar inverter transformer based unit has five working modes: DC priority, AC priority(A), AC priority(B), INV On and INV Off.
5.1 DC Priority (Must be connected with batteries)
The inverter converts DC input current from either the PV panels or battery bank into AC current to supply the load. When battery voltage is low, the inverter will automatically switch to the main input power (gr/generator) to supply to the load, but won’t recharge batteries with AC power. The system automatically switches back to DC after the batteries are charged by PV again.
5.1.1 PV with battery bank (when PV is sufficient))
5.1.2 Battery only (when PV is not available, but battery power is sufficient)
5.1.3 AC only (when PV is not available, and battery power is insufficient)
For more working mode ,pls contact with our sales
6 Wiring Diagram
7 Installation Site Case
Our factory's off grid inverter design scheme is based on power frequency, we have been producing
it for 12 years and maintain a good reputation. We have hundreds of thousands of installation case
images, limited to website space and only for display. We only list a small number of installation cases.
If necessary, please come to our factory to discuss and appreciate various cases. We actively seek agents,
wholesalers, and traders to cooperate with us, create brilliance together, and establish a great win-win
partnership.